Some Considerations for Suction and Return Pipework & Fittings

When building a DIY swimming pool, in your design you need to consider what pool fittings and pipework you are going to need. Fittings will be the suction side, taking water from the pool, Skimmers, Bottom Drains and if fitted a Vacuum Point. Then the return side being the return jets delivering flittered water back into the pool. The number of these fittings, the volume of water you have, the time required to pump and filter (turn time) this volume of water, sets the pump and filter size you will require. A point to mention: – A large oversized** pump and filter unit will not help your water clarity and more than likely hurt you pocket with inflated initial equipment cost and ongoing electricity bills.

 

If you propose to have pool heating, this requires a second flow consideration. The most cost affective and popular is an electric heat pump. You can also have a heat exchanger, run from either a dedicated gas boiler or the household heating system. Then there is full electric, as in burning electric similar to a heating element in a household kettle, a very simplistic explanation but you can guess the cost implication. All three of these systems can be supplemented with some solar but can be very inefficient in the UK for obvious reasons. We have even had pool and hot tub heating via wood burners……

 

Bottom Drains & Skimmers

Constructing with Bottom Drains comes with a safety consideration. The rule of thumb is to have two bottom drains, connected by a single Tee pipe with the bottom drains one on either side. This configuration allows if one drain is blocked the other side will still draw water reducing its suction force. Having just one suction point has obvious safety concerns if swimmers are held underwater by this force. Bottom drains are also of an advantage in mixing of the water column. Water being taken from the lowest water level along with skimmers on the pool surface. Another nice to have advantage is the ability to pump the pool dry if this is required for any maintenance. If you decide to you are going to have bottom drains they need to be laid and pressure tested before the pool concrete slab floor is laid. As for the wall fittings these need to be decided upon, how many and type, and built in as you block up the walls.

Skimmers do what they say on the tin. They create surface tension on the water that drags floating debris towards them, skims. And with a weir arrangement drops the water collecting any debris in the rear basket. Positioned with some common sense to create a natural flow on the pool surface with even the prevailing wind being taken into consideration can keep your pool swimmer ready at all times.

It is worth noting that the flow rates and the pressure rating for pool pipe is normally stated for positive pressure operation and not when pipe are used for negative pressure ie suction for drains and skimmers. The class D pipe we supply has a wall thickness sufficient to withstand 1 negative atmosphere and is therefore not a major issue. However we would always recommend drain and skimmer flow capacity to be in excess of the turn rate of the pump and filter setup.

 

Return Jets

Return jets need to be balanced out to cope with the water rate you intend to circulate and matched to your pump and filter rating. Return jets should come with a flow rating but on average work out to around 4m³ per hour each. The number required can be simply calculated and the total flow rate needs to be set above the flow of the pump and filter combination not to overstress the pipework and its fittings.  They also need to be positioned to mix the water column within the pool to minimise dead spots allowing all water to circulate. Obviously bathers will mix up the water but if the pool has infrequent use you need to ensure all water is mixed and filtered to avoid algae growth.

 

Pool Heating

Pool heating has its own flow considerations. Your heating source will have an optimum flow rate stated for best delivery of heat into your pool water. If the heating source has been sized correctly its optimum flow rate will be less than the turn rate of your pump and filter combo. Heating is normally installed with what is called a bypass circuit. This is a combination of 3 valves, firstly allowing for the optimum flow rate of your heat pump to be achieved, the remaining water allowed to “by-pass” on its way back to the pool. The second advantage is that of maintenance, the heater can be isolated out of the water flow enabling the pool still to be filtered and used.

So perhaps you can see a 2nd reason not to oversize** in the pump and filter department. It is counter productive having larger pumps and filters with their associated higher initial cost when they are not required to do their job as fast. When you can settle for the lower cost models (whilst maintaining quality) that will do the same job over a longer period closer to your required flow rate and your heating heating system time frame that it takes to transfer the heat into the water.

It would be the norm particularly with heat pumps in a domestic installation to have a turn rate of you pool of say 5 hours but to have double that 10 hours for the heat pump to work efficiently. A consideration these days is for a variable speed pump to be installed. This would allow a very low daily turn rate to be achieved with 24/7 filtration and have an inverter heat pump running continuously, dipping in and out as they do with very low power consumption.

The basic rules are: –